EasyManuals Logo

Siemens SINAMICS G120C Function Manual

Siemens SINAMICS G120C
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
Restriction with SINAMICS G120 Power Modules
You cannot use all of the integrated safety functions when using the following Power Modules:
Power Module Restriction
PM230 in degree of protec‐
tion IP55
Article numbers 6SL3223-0DE . . - . . A . :
The integrated safety functions are not possible.
Article numbers 6SL3223-0DE . . - . . G . :
The basic STO function is possible.
PM230 in degree of protec‐
tion IP20 and Push Through
Article numbers 6SL321 . -1NE . . - . . L . :
The integrated safety functions are not possible.
Article numbers 6SL321 . -1NE . . - . . G . :
The basic STO function is not possible.
Description
3.5 Restrictions when using safety functions
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD 29

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating

Related product manuals