Detailed description
2.12 Block descriptions
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
161
Note
The block must be called by the user program. The user must provide an instance DB with
any number for this purpose. The call is multi-instance-capable.
Example of a call for FB 9:
CALL FB 9, DB 109 (
Ack := Error_ack, //e.g., MCP RESET
OPMixedMode := FALSE,
ActivEnable := TRUE, //
MCPEnable := TRUE); // Enable for MCP switchover
Note
Input parameter “MCPEnable” must be set to TRUE to enable the MCP switchover. The
default value of these parameters is set in this way and need not be specially assigned when
the function is called.
Interrupts, errors
The output parameters "Alarm1" to "Alarm6" and "Report" exist as information in the PLC
and are output in the event of M:N errors visualized on the HMI by the appearance of alarms
410900 - 410906.
If execution of an HMI function has failed (and an appropriate error message cannot be
displayed), status parameter "ErrorMMC" is set to 'logical 1' (e.g., booting error, when no
connection is made).
Call example for FB 1 (Call in OB 100)
CALL "RUN_UP", "gp_par" (
MCPNum := 1,
MCP1In := P#I 0.0,
MCP1Out := P#Q 0.0,
MCP1StatSend := P#Q 8.0,
MCP1StatRec := P#Q 12.0,
MCP1BusAdr := 255, // Address of 1st MCP
MCP1Timeout := S5T#700MS,
MCP1Cycl := S5T#200MS,
MCP1Stop := TRUE, // MCP switched off
NCCyclTimeout := S5T#200MS,
NCRunupTimeout := S5T#50S);

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120