EasyManuals Logo

Siemens SINUMERIK 840D sl Function Manual

Siemens SINUMERIK 840D sl
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #239 background imageLoading...
Page #239 background image
Functions
2.6 Path acceleration for real-time events (channel-specific)
Basic logic functions: Acceleration (B2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
21
Effective
Effective Real-time event acceleration is only enabled in AUTOMATIC and MDA operating
modes in conjunction with the following real-time events:
NC-STOP/NC-START
Override modifications
Modification of the velocity default for "safely reduced velocity" within the context
of the "Safely Integrated" function
Ineffective Path acceleration for real-time events is ineffective for changes in path velocity that
are attributable to path planning during preprocessing for the channel, such as
contour curvatures, corners, kinematic transformation limitations, etc.
Real-time-event path acceleration is ineffective if the programmed value is smaller
than the path acceleration calculated during preprocessing for the path section
concerned.
Programming
For information about programming system variables in the part program or synchronized
actions, see Chapter: Programming.
2.6.2 Activation
Start-up (commissioning)
The function does not need to be activated.
2.6.3 Programming
Syntax
$AC_PATHACC =
path acceleration
Functionality
Real-time-event path acceleration is set via the channel-specific system variables.
Parameter:
Path acceleration
Value range: Path acceleration ≥ 0
Unit: m/s
2
Deactivation: $AC_PATHACC = 0
Application:
Part program
Static synchronized action

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based