Detailed description
2.12 Block descriptions
Power Line Basic PLC Program (P3)
2-126 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
PI service: SETUFR
Activate user frames
Function:
User frames are loaded to the NCK. All necessary frame values must be transferred to the
NCK beforehand by writing variables with FB 3.
Parameterization
Signal Type Value range Meaning
PIService ANY PI.SETUFR Activate
user frames
Unit INT 1 to 10 Channel
PI service: CONFIG
Reconfiguration
Function:
The reconfiguration command activates machine data, which have been entered sequentially
by the operator or the PLC, almost in parallel.
The command can only be activated when the control is in Reset or the program is
interrupted (NC stop at block limit). An FB 4 error checkback message is output if these
conditions are not fulfilled (state = 3).
Parameterization
Signal Type Value range Meaning
PIService ANY PI.CONFIG Reconfiguration
Unit INT 1
WVar1 INT 1 Classification
PI service: CANCEL
Execute cancel
Function:
The CANCEL command activates the Cancel function (in accordance with key on MMC).
Parameterization
Signal Type Value range Meaning
PIService ANY PI.CANCEL Cancel