Detailed description
2.12 Block descriptions
Power Line Basic PLC Program (P3)
2-202 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Warning
If several block calls (FC 15, FC 16, FC 18) are programmed for the same axis/spindle in the
PLC user program, then the functions concerned must be interlocked by conditional calls in
the user program. The conditional call of a started block (parameter Start or Stop = TRUE)
must be called cyclically until the signal state of output parameter Active or InPos changes
from 1 to 0.
Declaration
FUNCTION FC 16: VOID //PART_AX
VAR_INPUT
Start: BOOL ;
AxisNo: INT ;
IC: BOOL ;
DC: BOOL
Minus: BOOL ;
Plus: BOOL ;
Pos: INT ;
FRate: REAL;
END_VAR
VAR_OUTPUT
InPos: BOOL ;
Active: BOOL ;
StartErr: BOOL ;
Error : BOOL ;
END_VAR
Description of formal parameters
The table below lists all formal parameters of the PART_AX function:
Signal I/O Type Value range Remarks
Start I Bool
AxisNo I Int 1 - 31 No. of axis to be traversed
IC I Bool = Absolute direction input
1 = Incremental direction input
DC I Bool = Predefined direction
= Shortest path

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals