Detailed description
2.12 Block descriptions
Power Line Basic PLC Program (P3)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-223
Checkback signals from user interface for controlling displays
Operating modes and machine functions
Destination:
MCP LED
Source:
Interface DB (parameter ModeGroupNo)
AUTOMATIC DB11, ... DBX6.0
MDA DB11, ... DBX6.1
JOG DB11, ... DBX6.2
REPOS DB11, ... DBX7.1
REF DB11, ... DBX7.2
TEACH IN DB11, ... DBX7.0
All signals are ORed to obtain the LED checkback signals of the INC selections.
Destination:
MCP LED
Source:
Interface DB (parameter ChanNo)
INC 1 ... 10 000, INC Var. DB21, ... DBB41, Bit 0 to 5
INC 1 ... 10 000, INC Var. DB21, ... DBB47, Bit 0 to 5
INC 1 ... 10 000, INC Var. DB21, ... DBB53, Bit 0 to 5
Destination:
MCP LED
Source:
Interface DB (all axis DBs)
INC 1 ... 10 000, INC Var. DB31, ... DBB65, Bit 0 to 5
Channel signals
Destination:
MCP LED
Source:
Interface DB (parameter ChanNo)
NC Start DB21, ... DBX35.0
NC stop DB21, ... DBX35.2 or DB21, ... DBX35.3
Single block DB21, ... DBX0.4
Note
Direction key LEDs are controlled by operating the direction keys.
Axis selection and WCS/MCS LEDs are controlled by operating the relevant pushbutton
switch.