List of information - Central Unit
377
7SS52 V4 Manual
C53000-G1176-C182-3
10415 Diff-current superv. BZ (group
alarm) (Id-sup BZ G)
Monitoring OUT * * * LED BO 194 200 1 Yes
10416 Diff-current superv. BZ L1 (group
alarm) (Id-sup BZ L1 G)
Monitoring OUT * * * LED BO 194 201 1 Yes
10417 Diff-current superv. BZ L2 (group
alarm) (Id-sup BZ L2 G)
Monitoring OUT * * * LED BO 194 202 1 Yes
10418 Diff-current superv. BZ L3 (group
alarm) (Id-sup BZ L3 G)
Monitoring OUT * * * LED BO 194 203 1 Yes
10420 15V supply supervision central
unit (15V-superv CU)
Monitoring OUT on
off
* * LED BO 194 212 1 Yes
10421 24V supply supervision central
unit (24V-superv CU)
Monitoring OUT on
off
* * LED BO 194 213 1 Yes
10422 Battery supervision central unit
(Batt. superv CU)
Monitoring OUT on
off
* * LED BO 194 214 1 Yes
10423 Measured value superv. BU
(group alarm) (Meas sup BU G)
Monitoring OUT on
off
* * LED BO 194 216 1 Yes
10424 Supply voltage superv. BU (group
alarm) (Supply sup BU G)
Monitoring OUT * * * LED BO 194 215 1 Yes
10425 Isolator fault alarm (Isol flt alarm) Monitoring OUT * * * LED BO 194 186 1 Yes
10426 Failure of isolator aux. voltage
(g.a.) (Bay DC fail G)
Monitoring OUT * * * LED BO 194 185 1 Yes
10427 Isolator fault: run time (group
alarm) (Isol flt run G)
Monitoring OUT * * * LED BO 194 184 1 Yes
10428 Isolator position faulty (group
alarm) (Isol flt pos G)
Monitoring OUT * * * LED BO 194 183 1 Yes
10429 Failure in auto testing (group
alarm) (Flt autotest G)
Monitoring OUT * * * LED BO 194 210 1 Yes
10430 >Blocking of Breaker Failure Pro-
tection (>Blocking BF)
BF-Protection SP on
off
* * LED BI BO 194 164 1 Yes
10431 Blocking of Breaker Failure Pro-
tection (Blocking BF)
BF-Protection IntSP on
off
**LEDBO
10432 Breaker Failure Protection
blocked (BF blocked)
BF-Protection OUT on
off
* * LED BO 194 165 1 Yes
10433 Breaker Failure/Transfer Trip
(g.a.) (Transf. Trip G)
BF-Protection OUT * * m LED BO 194 180 2 Yes
10434 Timing error BF input (group
alarm) (BF BI error G)
BF-Protection OUT * * * LED BO 194 181 1 Yes
10435 Timing error BF release (group
alarm) (BF rel error G)
BF-Protection OUT * * * LED BO 194 182 1 Yes
10436 Trip command BF (group alarm)
(Trip BF G)
BF-Protection OUT * * * LED BO 194 176 2 Yes
10437 Timing error BF impulse input
(g.a.) (BF ImpBI errorG)
BF-Protection OUT * * * LED BO 194 189 1 Yes
10440 >TRIP commands blocking
(>TRIP blocking)
Device SP on
off
* * LED BI BO 194 162 1 Yes
10441 TRIP commands blocking (TRIP
blocking)
Device IntSP on
off
* * LED BO 194 154 1 Yes
10442 TRIP commands blocked (TRIP
blocked)
Device OUT on
off
* * LED BO 194 163 1 Yes
10443 BZ blocked selective (group
alarm) (Block BZ sel G)
BB Protection OUT * * * LED BO 194 192 1 Yes
10444 Blocking by supervision zero
crossing (Block ZeroCross)
Monitoring OUT * * * LED BO
10445 Device Trip (group alarm) (Device
trip G)
BB Protection OUT * * m LED BO 194 170 2 Yes
FNo.
Description Function Type
ofIn-
for-
matio
n
Log-Buffer Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Chatter Blocking
Type
Information No.
Data Unit
General Interrogation
www . ElectricalPartManuals . com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7SS522 V4.6 and is the answer not in the manual?

Siemens SIPROTEC 7SS522 V4.6 Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7SS522 V4.6
CategoryPower distribution unit
LanguageEnglish

Related product manuals