Home
Siemens
Controller
SIRIUS 3RW52
Page 174 (Wiring for Remote RESET)
Siemens SIRIUS 3RW52 - Wiring for Remote RESET
198 pages
Manual
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
Example c
ircuits
A.2
Contr
ol circ
uit con
necti
on
SIRIUS
3RW52 Soft Start
er
174
Manual
,
01/2019
,
A5E35630451002A/
RS
-
AD/004
A.2.6
Wiring for
remote RE
SET
Procedure
Result
You can res
et a p
ending er
ror
message
by oper
ating t
he reset
button f
or >
4
s.
173
175
Table of Contents
Main Page
Default Chapter
3
Table of Contents
3
1 Description
7
Target Group
7
Device Design
8
Operating Principle
9
Interaction Interfaces
11
Operating Modes and Master Control Function
12
Device Versions
14
Areas of Application / Load Types
16
Selection of the Soft Starter Using the Simulation Tool for Soft Starters
17
Structure of the Article Number
18
Accessories
20
Accessories for 3RW52 Soft Starter
20
3RW5 Communication Module
22
SIRIUS Soft Starter es (TIA Portal)
23
3Rw5 Hmi
24
Additional Documentation
27
Siemens Industry Online Support
29
Support Request
31
Siemens Industry Online Support App
31
2 Safety Information
33
ESD Guidelines
33
Reactive Power Compensation
35
Electromagnetic Compatibility (EMC) According to IEC 60947-4-1
35
Security Information
35
Recycling and Disposal
36
3 Mounting and Dismantling
37
Installing the 3RW52 Soft Starter
37
Mounting the Fan Cover
38
Mounting the 3RW52 Soft Starter on a Level Surface
40
Installing / Mounting / Removing 3RW5 HMI
42
Installing the Standard 3RW5 HMI in 3RW52 Soft Starter
42
Removing Standard 3RW5 HMI
43
Installing the High Feature 3RW5 HMI in the 3RW52 Soft Starter
44
Removing the High Feature 3RW5 HMI
45
Installing the Standard 3RW5 HMI into the Control Cabinet Door
46
Installing the High Feature 3RW5 HMI in the Control Cabinet Door
49
Installing the Standard 3RW5 HMI on a Flat Surface
53
Installing the High Feature 3RW5 HMI on a Flat Surface
55
Cut out the Hinged Cover for 3RW5 HMI
57
Replacing the Hinged Cover of the 3RW52 Soft Starter
58
4 Wiring
59
Connections
59
Overview of All Connections
59
State Diagrams of the Inputs and Outputs
61
Connecting the 3RW52 Soft Starter
63
Connect the 3RW52 Soft Starter to the Main Circuit Connection (Line Side / Motor Side)
64
Mounting Terminal Covers on Main Circuit Connections
66
Replacing the Terminals on Size 2 Devices
67
Connecting the Control Terminals (Screw Terminals)
69
Disconnecting the Control Current Form the Screw-Type Terminals
70
Connecting the Control Terminals (Spring-Type Terminals)
71
Disconnecting the Control Current from the Spring-Loaded Terminals
72
Replacing the Control Terminals
73
Installing the Cover for the Control Cable Duct
75
Removing the Cover of the Control Cable Duct
76
5 Parameter Assignment
77
Setting Elements on the 3RW52 Soft Starter
77
Overview of Parameters
80
Suggested Settings
81
Parameterizing the 3RW52 Soft Starter
82
Setting RESET MODE and Soft Torque
83
Reset Modes
85
Parameterizing Output 13 / 14 (Output Signal on or RUN)
86
6 Commissioning
89
Commissioning the 3RW52 Soft Starter
89
Sealing the 3RW52 Soft Starter
90
First Commissioning of the High Feature 3RW5 HMI
91
7 Functions
93
Soft Starting
93
Current Limiting Function
96
Soft Stopping
98
Motor Protection
99
Electronic Motor Overload Protection
99
Thermistor Motor Protection with Temperature Sensor (Optional)
100
Intrinsic Device Protection
101
Soft Torque
102
Additional Parameters
104
Standard 3RW5 HMI
105
Design of the Standard 3RW5 HMI
105
Standard 3RW5 HMI Menu
107
High Feature 3RW5 HMI
110
Design and Operator Controls of the High Feature 3RW5 HMI
110
Main Menu of the High Feature 3RW5 HMI with the 3RW52 Soft Starter
112
Parameterizing the High Feature 3RW5 HMI
116
Monitoring
117
Monitoring the Measured Values of the 3RW52 Soft Starter with the High Feature 3RW5 HMI
117
Monitoring the Process Image of the 3RW52 Soft Starter with the High Feature 3RW5
118
Hmi
118
Parameterizing Analog Output AQ Via the High Feature 3RW5 HMI
119
Overview
121
Defining the Local Access Protection (PIN)
122
Micro SD Card
124
8 Messages and Diagnostics
127
Diagnostics Options
127
LED Display
128
Overview of the Device Leds of the 3RW52 Soft Starter
128
Status and Error Displays
129
Led State / Overload
130
Overview of Leds on Standard 3RW5 HMI
131
Overview of Leds on High Feature 3RW5 HMI
132
Warnings and Remedial Measures
133
Faults and Remedial Actions of the 3RW52 Soft Starter
134
Faults and Remedial Actions on the 3RW5 HMI High Feature
138
Reset Modes
139
Diagnostics of the 3RW52 Soft Starter with the 3RW5 HMI High Feature
140
Diagnostics of Communication with the High Feature 3RW5 HMI
142
Execute HMI Diagnostics with the 3RW5 HMI High Feature
142
Logbooks
143
9 Maintenance and Servicing
145
Maintenance and Repairs
145
User Test
146
Firmware Update
149
Performing Firmware Update with Micro SD Card (3RW5 HMI High Feature)
150
Restore Factory Setting
151
Restoring the Factory Settings Via High Feature 3RW5 HMI
152
Restoring the Factory Settings with the Master RESET Button Via 3RW5 HMI High Feature
153
10 Technical Specifications
155
Technical Data in Siemens Industry Online Support
155
11 Dimension Drawings
157
Cax Data
157
12 Circuit Diagrams
159
Cax Data
159
Example Circuits
161
Main Circuit Connection
161
Feeder Assembly, Type of Coordination 1 Fuseless
161
Feeder Assembly, Type of Coordination 1 with Fuses
162
Feeder Assembly, Type of Coordination 2
163
Inside-Delta Circuit
164
Control Circuit Connection
167
Control by Pushbutton
167
Control by Switch
168
Switching with the Control Supply Voltage
169
Control by PLC
171
Actuation of a Line Contactor
172
Wiring for Remote RESET
174
Connecting the Temperature Sensor
175
Connecting the Evaluation Unit to the Analog Output
176
Special Applications
177
Controlling a Motor with a Magnetic Parking Brake
177
EMERGENCY STOP Shutdown to SIL 1 or PL C with a 3SK1 Safety Relay
179
Wiring of the 3SK1 Safety Relay SIL 1 with Line Contactor
181
Wiring of the 3SK1 Safety Relay SIL 1 Without Line Contactor
182
EMERGENCY STOP Shutdown to SIL 3 or PL E with a 3SK1 Safety Relay
183
Wiring of the 3SK1 Safety Relay SIL 3 with Line Contactor
185
Wiring of the 3SK1 Safety Relay SIL 3 Without Line Contactor
186
Contactor for Emergency Start
187
Third-Party Software
189
Information about Third-Party Software
189
Glossary
193
Index
195
Other manuals for Siemens SIRIUS 3RW52
Equipment Manual
258 pages
Related product manuals
Siemens SIRIUS 3RW55
238 pages
Siemens SIRIUS 3RW50
238 pages
Siemens SIRIUS 3RW5 series
106 pages
Siemens PROFINET SIRIUS 3RW5
214 pages
Siemens SIRIUS 3RW40
204 pages
Siemens SIRIUS 3RW44
262 pages
Siemens SIRIUS 3RW30
204 pages
Siemens SIRIUS 3RW40 2
32 pages
Siemens Sirius 3RW44 V.6.2
34 pages
Siemens SIRIUS 3RW44 2 Series
46 pages
Siemens SIRIUS 3RW40 24 Series
32 pages
Siemens SIRIUS 3RM1
196 pages