Mounting and dismantling
3.4 Installing / mounting / removing 3RW5 HMI
SIRIUS 3RW52 Soft Starter
Manual, 01/2019, A5E35630451002A/RS-AD/004
53
3.4.7 Installing the Standard 3RW5 HMI on a flat surface
Requirements
● Note the mounting positions, minimum clearances and ambient conditions stated on the
data sheet.
● 3RW5 HMI Standard (accessories)
● Level surface, e.g. sufficiently strong mounting plate
● 2 correctly implemented bore holes
● 2 cap screws M4 x 12 DIN ISO 7045 to fit the bore holes
● Screwdriver (depending on the drive of the screws)
● Push-in lugs for wall mounting (accessories)
● Connected HMI connecting cable of suitable length (accessories)
Procedure
● Observe the coding of the plug and socket ①.
● Lock the connector in the socket
②.
● Observe the cable routing in the cable duct
– Cable routing to the bottom