Mounting and dismantling
3.4 Installing / mounting / removing 3RW5 HMI
SIRIUS 3RW52 Soft Starter
Manual, 01/2019, A5E35630451002A/RS-AD/004
49
3.4.6 Installing the High Feature 3RW5 HMI in the control cabinet door
Requirements
● Note the mounting positions, minimum clearances and ambient conditions stated on the
data sheet.
● 3RW5 HMI High Feature (accessories)
● An HMI connecting cable (accessory) of suitable length
● Cutout of suitable size in the control cabinet door
● PZ2 screwdriver in installation with door mounting kit IP65
● Device depth of the High Feature 3RW5 HMI:
– Total depth: 32 mm
– Embedded depth: 26 mm
● Permissible wall thickness of the cabinet door:
– Without IP65 door mounting kit: 1.5 to 3.0 mm
– With IP65 door mounting kit: 1.0 to 7.0 mm
● Optional accessories:
– IP65 door mounting kit
Procedure without door mounting kit IP65
Place the 3RW5 HMI High Feature in the cutout of the control cabinet door ①. Ensure that
the 3RW5 HMI High Feature engages audibly in the 4 fixtures
②.