2-46
1010PFM-3GSection 2
2.8.1 SELECT DATA
The [Select Data] option list allows you to select a data function for the on-screen stripchart display.
The stripchart provides a data plot using the selected data units and time base. All data items except
Valc and Vaer use the span settings from the Data Span/Set/Cal menu. The following Data Items are
available for the Stripchart Display:
§ Vfo ........................... (spanned flow) *default
§ Vfab ......................... (spanned unsigned flow magnitude)
§ Temp ....................... (Temperature)
§ Vs ............................ (sonic velocity)
§ Valc.......................... (signal amplitude)
§ Vaer ......................... (aeration/cavitation)
To select a data item for the stripchart:
To access the [Select Data] option list press
Move the cursor to the desired item by pressing
To store your selection press
2.8.2 DATA DISPLAY
The [Data Display] option list allows you to select a format for the stripchart plot. It offers the choice of
displaying data either in the current data rate units or as a percent of span defined in the Data Span/Set/
Cal menu. [Data Rate Units] is the default selection.
To select a format for the data display:
To access the [Data Display] option list press
To move the cursor to the required scale unit press
To store your selection press
ENT
ENT
Siemens Dual Path SITE1
Select Data Units or Percent Display
Stripchart Setup
Select Data LiquIdent
Data Display Data Rate Units
Time Base 1 second
Stripchart Clear Yes
Use this menu cell
to select an update
interval for the
stripchart.
Use this menu cell
to clear the current
stripchart.
Use this menu cell
to select a data
item to display on
the stripchart.
Use this menu cell
to select whether
the stripchart
shows data as
either a rate or a
percentage of
span.