5. Once transducer is in place, secure with the transducer clamping screw. Do not overtighten. Ob-
serve the upstream/downstream orientation and connect the transducer cable to the computer’s
input jack. If a dual-channel unit, make sure you connect the cable to the input jacks of the correct
channel. Repeat this procedure for the number index transducer.
Installing a 1012T Mounting Track in Direct Mode
Paragraph 2.4 describes the Installation procedures that lead up to the automatic selection of trans-
ducers, mounting mode and spacing method. Shown is a Model 1012T mounting track to accommo-
date size B3 universal transducers. Examine the figure below which shows a typical Pick/Install Xdcr
menu screen. Note the automatic assignment of model numbers for the transducer and mounting
track, plus the designation of number index.
1. Perform all required menu steps up until the point where the flow computer prompts you to press
<ENT> to finish the transducer install routine. Note the reported number index.
You will be inserting an index pin into this hole and the reference hole. Check to ensure that you
have a matched set of transducers. They both should have the same S/N number but marked with
either an “A” or “B” (e.g., 100A and 100B).
2. The direct mount configuration uses two track rails, one for each transducer, installed 180
0
apart on
the pipe. One track rail includes the tension screw while the other has a locating stud to support the
chain (see below and on next page).
Transducer Model 1011 Universal
Transducer Size B3
Xdcr Mount Mode Direct
Spacing Offset Minimum
Number Index 4
Spacing Method Track 1012TP
Ltn Value (in) 0.217
Install Completed? No
Empty Pipe Set Channel Not Setup
Zero Flow Adjust Channel Not Setup
Siemens 2 Channel [1] SITE1
Key [Install] after mounting transducers
Pick/Install Xdcr
Note selection of track
P/N, Mount Mode and
Number Index.
INSTALLATION – DIRECT MOUNT 180º OPPOSED WITH MOUNTING TRACK
Upstream
Transducer
Chain
Tensioning
Screw
Transducer Clamping
Screw
Downstream
Transducer
Number
Index Pi
n
TOP VIEW
Ç
Track Rails
Upstream
Transducer
Transducer Clamping
Screw
Chain Tensioning
Screw
Track Rails
Downstream
Transducer
Number
Index Pin
TOP VIEW
ÏÏ
ÏÏ
Ï

Table of Contents

Other manuals for Siemens SITRANS F

Related product manuals