1-14
1010PFM-3G
Section 1
Multiple Select Option Lists
Certain option lists allow you to make more than one selection. For example, the Datalogger Data
option list allows you to select any or all of the available data items for your reports. As previously
described, you can use to move the cursor through the list.
However, if you press to select an item,a plus sign (+) appears next to that item. The cursor re-
mains within the option list so that you can make other selections. To deselect a previously selected
item, move the cursor next to that item and then press . You press to leave a multiple select
option list.
Entering Numeric Data
When a menu cell requires a numeric answer, press to access a number entry field; an equal sign
(=) appears before the current entry. You can now use the number keys and the decimal point key to
type a new value. If applicable, you can use <+/-> key to change the mathematical sign of the number.
Press to store the numeric data.
NOTE: All Numeric Data cells provide a four-function calculator via the keypad’s arithmetic
function keys.
ENT
CLR
ENT
Siemens 2 Channel [1] 1
Datalogger Mode +Site Id
Datalogger Data +Date
Log Time Interval +Time
Datalogger Events Flow
Display Datalogger +Average Flow
Raw Flow
Total
Vs
Valc
Select Datalogger Data
Datalogger Setup
Siemens 2 Channel [1] Channel 1
Select Liquid 20% Ethyl Glycl
Estimated Vs m/s 1600
Viscosity cS 2.00
Density SG 1.030
Access Liquid Option List
Liquid Class
Siemens 2 Channel [1] Channel 1
Select Pipe Class Manual Entry
Select Pipe SizeN/A
Pipe OD (in) = 0.500
Pipe Material Steel
Wall Thickness 0.100
Liner Material None
Liner Thickness 0.000
Enter pipe Outer Diameter manually
Pipe Data