9.2.4.3 Volume and mass flow measurements
The following characteristic curves are available for volume and mass flow measurements:
Hold at 0, square root (VSOFF
, for volume or MSOFF, for mass flow)
The loop current is 4 mA up to the application point (low flow cut-off (Page 132)). Starting
from the application point, scaling occurs according to the square root:
$SSOLFDWLRQSRLQW
6HWWLQJUDQJH
IRUDSSOLFDWLRQSRLQW






EDU
;
Y Loop current or flow
X Set measuring span
Linear, square root
(VSLN, for volume or MSLN, formass flow)
The loop current has a linear relationship with the differential pressure up to the application
point (Page 119). Starting from the application point, scaling occurs according to the square
root:
$SSOLFDWLRQSRLQW
OL
QHDU
6HWWLQJUDQJH
IRUDSSOLFDWLRQSRLQW






EDU
;
Y Loop current or flow
X Set measuring span
Parameter assignment