10.1.5.2 Safety-related parameters
The following parameters are the safety-related parameters of the device:
Parameter ID Parameter name on
the display
Meaning
S1 PV SELECT Pressure is the primary variable. The parameter cannot be
changed.
S2 DAMPING Damping value [04] (Page 110)
S3 UPPER RANGE Set upper range value parameter [03] (Page 108)
S4 LOWER RANGE Set lower range value parameter [02] (Page 108)
S5 APPLICATION Application [05] (Page 110)
S6 OVERLD BEHAV Overload behavior [36] (Page 145)
S7 SATURAT HIGH Upper saturation limit (Page 126)
To set these parameters, change the device mode to "Functional Safety disabled".
10.1.5.3 Device mode "Functional Safety enabled"
In "Functional Safety enabled" device mode, an internal diagnostics process of the device
performs the following safety-related checks:
Sensor breakage monitoring
Continuous testing of execution and logic behavior of CPU, analog-to-digital converter and
memory
Temperature monitoring
Pressure monitoring, depending on the setting of the Overload behavior [36] (Page 145)
parameter.
Integrity of safety-related parameters
Plausibility check of current output
When a safety-related critical error is detected in the device, the current output signal
corresponds to the fault current (≤ 3.55 mA) and is independent of the settings of the following
parameters:
Select fault current [10] (Page 124),
Lower fault current [11] (Page 124),
Upper fault current [12] (Page 125),
Lower saturation limit [13] (Page 125),
Note
As long as the device is in the "Functional Safety enabled" device mode, all parameters are
protected against changes.
To change the parameters, disable Functional Safety.
Functional Safety