Rotating the stainless steel enclosure
1. Loosen the front retaining screw by half a rotation.
2.
Loosen the back retaining screw by half a rotation.
3. Rotate the enclosure to the desired position (but no further than the end stop).
4. Tighten the front and back retaining screw.
To prevent the enclosure from turning in case of vibration, make sure that the front and back
retaining screw are tightened.
5.8 Removing
WARNING
Incorrect disassembly
The following risks may result from incorrect disassembly:
- Injury through electric shock
- Risk through emerging media when connected to the process
- Risk of explosion in hazardous area
In order to disassemble correctly, observe the following:
Before starting
work, make sure that you have switched off all physical variables such as
pressure, temperature, electricity etc. or that they have a harmless value.
If the device contains hazardous media, it must be emptied prior to disassembly. Make
sure that no environmentally hazardous media are released.
Secure the remaining connections so that no damage can result if the process is started
unintentionally.