Service and maintenance
11
11.1 Basic safety instructions
The device is maintenance-free. However, a periodic inspection according to pertinent
directives and regulations must be carried out.
An inspection can include, for example, check of:
Ambient conditions
Seal integrity of the process connections, cable entries, and cover
Reliability of power supply, lightning protection, and grounds
WARNING
Dust layers above 5 mm
Risk of explosion in hazardous areas. Device may overheat due to dust build up.
Remove dust layers in excess of 5 mm.
WARNING
Use of a computer in a hazardous area
If the interface to the computer is used in the hazardous area, there is a risk of explosion.
Ensure that the atmosphere is explosion-free (hot work permit).
CAUTION
Releasing button lock
Improper modification of parameters could influence process safety.
Make sure that only authorized personnel may cancel the button locking of devices for
safety-related applications.
NOTICE
Penetration of moisture into the device
Device damage.
Make sure when carrying out cleaning and maintenance work that no moisture penetrates
the inside of the device.
SITRANS P320/P420 with 4 to 20 mA/HART
Operating Instructions, 11/2019, A5E44852162-AC 181