5.7 Rotating the enclosure
Introduction
To
make
the device easier to operate in any mounting position, you have the option of adjusting
the position of the enclosure within a range of 360°.
Retaining screw
One retaining screw for the aluminum enclosure and two retaining screws (front and back)
for the stainless steel enclosure prevent that the flat ribbon cable is damaged while rotating the
enclosure.
The flat ribbon cable connects the sensor to the electronics.
The tightening torques of the retaining screws are different for the aluminum enclosure and the
stainless steel enclosure. For the tightening torques of the retaining screws, refer to section
Torques (Page 238).
Requirement
You have a 2.5 mm Allen key.
Rotating the aluminum enclosure
1. Loosen the retaining screw by half a rotation.
2. Rotate the enclosure to the desired position (but no further than the end stop).
3. Tighten the retaining screw.
Installing/mounting
5.7 Rotating the enclosure
SITRANS P320/P420 with 4 to 20 mA/HART
Operating Instructions, 11/2019, A5E44852162-AC 63