Operating conditions for level
Installation conditions
Installation instruction
Specified by the flange
Ambient conditions
Ambient temperature
Note Observe the allocation of the max. permissible operating temperature to the max. permissible
operating pressure of the relevant flange connection.
Enclosure -40 … +100 °C (-40 … +212 °F)
Measuring cell with sili‐
cone oil filling
-40 … +85 °C (-40 … +185 °F)
Display -20 … +80 °C (-4 … +185 °F)
Storage temperature
-50 … +85 °C (-58 … +185 °F)
Climate class in accordance
with IEC 60721-3-4
4K4H
Degree of protection accord‐
ing to IEC/EN 60529/UL50-E
Enclosure with appropriate cable
gland
IP66/Type 4X
IP68 (2 hours at 1.5 m)
Enclosure with mounted M12 device
plug and/or lightning protection
1)
IP66/Type 4X
Enclosure with mounted HAN device
plug
1)
IP65
Electromagnetic compatibili‐
ty
Interference emission and
interference immunity
In accordance with EN 61326 and
NAMUR NE 21
Process medium conditions
Process temperature
Measuring cell with sili‐
cone oil filling
Plus side: See mounting flange
Minus side: -40 … +100 °C
(-40 … +212 °F)
1)
Only for non-Ex devices, not approved for use in Ex areas (ATEX, IECEx, FM, CSA)
Technical data
13.5 Operating conditions
SITRANS P320/P420 with 4 to 20 mA/HART
232 Operating Instructions, 11/2019, A5E44852162-AC