Explosion protection in accordance with FM (USA)
FM19US0155X The permissible operating values can be found in the certificate.
Order variants Identification
7MF0..0-.....-.B..-Z Class I, Zone 0, AEx ia llC T4/T6 Ga
Class I, Zone 1, AEx ib llC T4/T6 Gb
lntrinsically Safe (lS) for Class l, DIV 1, Gr. A-D
7MF0..0-.....-.C..-Z Class l, Zone 0/1, AEx ia/db llC T4/T6 Ga/Gb
Explosion Proof (XP) for Class l, DIV 1, Gr. A-D
7MF0..0-.....-.D..-Z Class I, Zone 0, AEx ia llC T4/T6 Ga
Class l, Zone 0/1, AEx ia/db llC T4/T6 Ga/Gb
lntrinsically Safe (lS) for Class I, DIV 1, Gr. A-D
Explosion Proof (XP) for Class l, DIV 1, Gr. A-D
7MF0..0-.....-.L..-Z Class ll, Zone 21, AEx tb lllC T120°C Db
Class ll, Zone 22, AEx tc lllG T120°C Dc
Class l, Zone 2, AEx ec llC T4/T6 Gc
Dust lgnition Proof (DlP) for Class ll, DIV 2, Gr. E-G, Class lll
Non incendive (NI) for Class I, DIV 2, Gr. A-D
7MF0..0-.....-.M..-Z Class ll, Zone 20, AEx ia lllC T120°C Da
Class l, Zone 0, AEx ia llC T4/T6 Ga
Class ll, Zone 21, AEx tb lllC T120°C Db
Class l, Zone 2, AEx ec llC T4/T6 Gc
lntrinsically Safe (lS) for Class ll, DIV 1, Gr. E-G; Class lll
lntrinsically Safe (lS) for Class l, DIV 1 Gr. A-D
Dust lgnition Proof (DlP) for Class ll, DIV 2, Gr. E-G; Class lll
Non incendive (Nl) for Class l, DIV 2, Gr. A-D
7MF0..0-.....-.S..-Z Class l, Zone 0/1, AEx ia/db llC T4/T6 Ga/Gb
Class l, Zone 0, AEx ia llC T4/T6 Ga
Class ll, Zone 21, AEx tb lllC T120°C Db
Class l, Zone 2, AEx ec llC T4/T6 Gc
7MF0..0-.....-.T..-Z Class l, Zone 0/1, AEx ia/db llC T4/T6 Ga/Gb
Class l, Zone 0, AEx ia llC T4/T6 Ga
Class ll, Zone 21, AEx tb lllC T120°C Db
Class l, Zone 2, AEx ec llC T4/T6 Gc
Explosion proof (XP) for Class I, DIV 1 Gr. A-D
lntrinsically Safe (lS) for Class l, DIV 1 Gr. A-D
Dust ignition proof (DlP) for Class ll, DIV 2, Gr. E-G; Class lll
Non-incendive (Nl) for Class l, DIV 2, Gr. A-D
Technical data
13.10 Certificates and approvals
SITRANS P320/P420 with 4 to 20 mA/HART
Operating Instructions, 11/2019, A5E44852162-AC 241