Communication
11.4 DR 3 Belt scale parameters
SIWAREX WT241
Manual, 05/2015, A5E36046748Aa 99
Variable
Note
Type
L
Rw
Default
Min.
Max.
Register
Scale name header
Maximum length and
actual length of string for
scale name
UBYTE[2]
2
rw
12.12
-
-
1004
Scale name
(Page 101)
Scale name specified by
user
CHAR[12]
12
rw
" "
-
-
1005
Code for regulations
(Page 101)
0: No verification
1: OIML R50
2: NTEP Book 44
USHORT
2
rw
0
-
-
1011
Unit for belt load
(Page 102)
0=kg/m, 1=lbs/foot
USHORT
2
rw
0
-
-
1012
Unit for flow rate
(Page 102)
0=t/h, 1=kg/h, 2=T/h,
3=TL/h, 4=lbs/h
USHORT
2
rw
0
-
-
1013
Resolution of weight
and belt load
(Page 102)
Resolution (1*10**k,
2*10**k, 5*10**k]; k: -3 …
2 )
FLOAT
4
rw
0.01
-
-
1014
Resolution of flow
rate (Page 103)
Resolution (1*10**k,
2*10**k, 5*10**k]; k: -3 …
2 )
FLOAT
4
rw
0.1
1016
Resolution of master
totalizer (Page 103)
Resolution (1*10**k,
2*10**k, 5*10**k]; k: -3 …
2 )
FLOAT
4
rw
0.1
1018
Design flow rate
(Page 103)
Customer input according
to rated data
FLOAT
4
rw
360
1020
Weigh length
(Page 103)
FLOAT
4
rw
1
1022
Belt length
(Page 104)
Is measured and entered
by the user.
FLOAT
4
rw
30
1024
Number of belt revo-
lutions (Page 104)
Number of belt revolu-
tions relevant to meas-
urement,
specification applies to
calibration and zero set-
ting commands
USHORT
2
rw
1
1026
Speed detection
(Page 104)
0: No sensor, speed is
specified or determined.
1: One sensor
2: External specification
of speed via DR19
USHORT
2
rw
1
1027
Design speed
(Page 104)
Maximum speed with
empty belt
FLOAT
4
Rw
1
1028
Speed correction if
belt loaded
(Page 104)
Only relevant if no sensor
present. Percentage de-
viation in speed when belt
is loaded (see next pa-
rameter)
FLOAT
4
rw
0.98
1030