FS 70 Installation Instructions
974-24007001/5.0 63
NOTE: The Processing Unit and the Power/TTM must be connected to a dedicated
UPS.
4.2.2 Ship Power Requirement
The display unit, generally, will require 120 VAC or 230 VAC. Depending on the
capabilities of the unit chosen, it may automatically detect the supply voltage or the unit
may have to be ordered for the correct voltage.
The FS70 Processor will operate from either 120 VAC or 230 VAC. IF input voltage must be
selected then a voltage input selector switch is located at the rear of the unit. Some of the
processors are equipped with auto detection voltage input.
The FS Power Supply/TTM module can be operated with either 120 VAC or 230 VAC.
Selection of the supply voltage is done by moving the voltage selector card located in the
power entry module at the rear panel. Details on selecting the proper voltage are indicated on
the voltage card. You must position theindicator pin” location to the desired voltage.
To change the input line voltage, use a small blade screwdriver and pop the cover. Pull the
voltage selector card straight out from the housing, and place the indicator pin to the
selected voltage. Reinsert the card, reinstall the cover and verify that the indicator shows
the desired voltage. You must insure that the proper fuse rating is installed, 2 A for 230
VAC and 4 A for 110 VAC. Spare fuses are supplied with the TTM module.
NOTE: Failure to select the proper input voltage will damage the internal power
supply.
4.2.3 Display Unit
Either an LCD/DVI or VGA monitor may be connected to the FS70 Processor. Depending
on which type of monitor is used, the video output type must be set accordingly.
An industry standard VGA monitor will connect directly to the miniature DB-15 connector
located on the rear panel of the processor unit.
The FS70 Processor Unit has a Dual Video interface card installed as standard equipment.
You must set up your display software as per your requirement. If you have only one
monitor, simply plug your monitor cable into the monitor “Y adaptor connector marked
“Connector 1” on the adapter card. If you are using two monitors, you must connect the 2
nd
monitor to the “Connector 2” on the adapter card.
NOTE: The FS 70 Processor must be is turned “OFF” prior to connecting the video
monitors
A User Guide manual is provided with the system including a Recovery CD-ROM. With this
CD you can recover your system as delivered and run the diagnostics.