114
406388/B
Relatedtopics
PXTrawlEyeConguratordialogbox,page229
PXMultiSensormk2Conguratordialogbox,page236
MainPXSensorscongurationparameters,page264
SpeciccongurationparametersforPXTrawlEyesensors,page267
Overviewofsensorschannelsandfrequencies,page269
ConguringaPXUniversalandaPXMultiCatchsensorforaSR
typereceiverunit
CatchmonitoringsensorsaredeliveredfromKongsbergMaritimeASreadilysetupwith
commondefaultsettings.Whenrequired,eachindividualsensormaybeconguredto
specifyitscommunicationchannelandwhichmeasurementstomake.
Prerequisites
ThisprocedureassumesthatasuitablereceiverunithasbeenconnectedtotheProcessor
Unit,andthatallrelevantcommunicationparametershavebeendened.
Context
ThePXConguratordialogboxesallowyoutosetupwhichmeasurementsthesensorshall
make,thecommunicationchannelandsomeotherrelevantparameters.
Dependingonyourhardwarecongurationandthetypeofsensor,youmayconguretwo
measurementsoruptove.
Note
TheTV80onlyallowsyoutocongurePXsensors.Ifyouwishtouseoldersensors(notPX
family),thesemustbeconguredusingtheirdedicatedapplicationsbefore
youaddthem.
Procedure
1OpentheSetupmenu.
2OntheSetupmenu,selectInstallation.
ObservethattheInstallationdialogboxopens.
3AtthebottomoftheSensorlistpage,selectAddNewSensor.
TheAddNewSensordialogboxopens.
4SelectY es.