406388/B
47
3ObservetheI/OSetuppageontherighthandsideoftheInstallationdialogbox.
Everyinterfaceispresentedasasmall"blockdiagram".
4Ontherelevantseriallinecommunication,select
theinspectionpointattheleftsideoftheporticon
inthe“blockdiagram”.
ThePortMonitordialogboxopens.
ThePortMonitordialogboxallowsyoutostudythecommunicationstreamonthe
chosenseriallineport.
Note
ThePortMonitordialogboxisatoolfordebuggingpurposes.Itisneitherrequirednor
intendedfornormaloperationoftheTV80.
5Verifythatthecommunicationportisfunctional.V erifythatthedataowontheinput
line(RxDatatexteld)isoperational.
Inordertomonitorthisdataow,theperipheralsystemmustbeactiveandtransmitting
informationtotheTV80.
Ifthedataowisnot present,wesuggestthefollowingactions:
•Checkthattheperipheralsystemhasbeenswitchedon.
•Checkthattheperipheralsystemisinfacttransmittinginformation.
•Checkthecables.
•Checkthatyouhavemadethephysicalconnectiontothecommunicationportthat
youaremonitoring.
6SelectOKtoclosethePortMonitordialogbox.
Checkingthesensorsreadings
TheMeasurementsdialogboxdisplaysallthereadingstheTV80iscurrentlyreceiving
fromthesensorsinstalled.EveryexternalequipmentconnectedtotheTV80offersoneor
moremeasurements.
Prerequisites
ThisprocedureassumesthattherelevantsensorhasbeenconnectedtotheTV80Processor
Unit.
Context
IntheMeasurementsdialogbox,youcaneasilyseeallthemeasurementsreceivedina
specicportandiftheTV80isvalidatingit.Withjustalookyoucaneasilyidentify
Gettingstarted