128
406388/B
4Observethenumericalpresentationofthesensordepth,andallowthereadingto
stabilizeitself.
5OntheSetupmenu,selectCalibration.
6Selecttheinputsystemfromtheavailablelist.
7SelectStartCalibration.
8Waitforthesystemtodothecalibration.
Thedialogboxwillclosewhenthecalibrationprocessisnished.
9Observethenumericalpresentationofthesensordepth,andverifythatitreads1meter.
10SelectClosetosavethechosensettingsandclosethedialogbox.
11Retrievethesensorfromthewater.
Relatedtopics
Calibrationdialogbox,page214
Performingarsttimecalibrationoftherollandpitch
measurementsofaPXMultiSensor
IfyouwishtousethePXMultisensortomeasurethepitchandrollofthetrawldoors,you
mustcalibratethesensor.YoucancalibrateasensorinthePXMultiSensorCongurator
dialogbox.
Prerequisites
Calibrationmustbedonewiththesensormountedinitsinstallationadapteronthetrawl
door(s).
ThePXMultiSensorConguratordialogboxisonlyavailableif:
Youhaveconnectedthesensortoyoucomputerthroughtheconguratorcable.
Thereisareceiverunitconnectedtothesystem.
Context
Wheneverasensorismountedonatrawldoor,thepitchandrollmeasurementsneedtobe
calibrated.Ifyoudonotcalibrateyoursensorsyouwillnotknowifthepitchandroll
readingsarecorrect.Ifexistingsensorshavebeenreplaced,ornewsensorshavebeen
installed,anewcalibrationisalwaysrequired.