406388/B
129
Procedure
1Placethesensorinthedooradapter.
Ontheportdoor,the“down”elementshallfacedown.Onthestarboarddoor,the
“side”elementshallfacedown.
2Placethedooronastablesurface.Usealevelandsetthedoorincorrectupright
positiontocreatea0degreespitchand0degreesrollreference.
3OpentheSetupmenu.
4OntheSetupmenu,selectInstallation.
ObservethattheInstallationdialogboxopens.
5AtthebottomoftheSensorlistpage,selectAddNewSensor.
TheAddNewSensordialogboxopens.
6SelectY es.
7InthePXSensorConguratordialogbox,selectcommunicationportandsensortype,
thenselectConnect.
ThePXMultiSensorConguratordialogboxopens.
8SelectCalibrateSensor.
The(Pitchandroll)Calibrationdialogboxopens.
9Providedthatthedoorisinlevel,selectLeveled.
10Tiltthedooratleast20degreesintherolldirectionandmakesurethephysicaldoor
pitchdoesnotchange.
Thedoormustbetiltedatleast20degreestogetacorrectcalibration.
11Oncethedoorisstableinthetiltedposition,selectTilted.
Thesensorisnowoffsetadjustedforthatspecicdoor.
12SelectSettoacceptthevalues.
Result
Theselecteddoorsensoriscalibratedforthepitchandrollmeasurements.
Relatedtopics
AddNewSensordialogbox,page227
PXMultiSensormk2Conguratordialogbox,page236
MainPXSensorscongurationparameters,page264
Operatingprocedures