254
406388/B
Catch/BottomFilter
TheCatch/BottomFilterisusedtorestrictthechangeofstatefromthecatchand
bottomcontactsensors.Thiswillreducejitterinthepresentation.Whenthelteris
switchedoffanychangeinmeasurementstatuswillimmediatelybeshowninthe
presentation.ThedefaultsettingofthelterisWeak.
Thefollowingoptionsareavailable.
Off
Thelterisswitchedoff.
Weak
Theinformationprovidedfromthesensorsmustbestableforatleasttwo
consecutivetransmissions.Ifthisisnotthecase,theinformationisnotshownin
theTV80presentation.
Medium
Theinformationprovidedfromthesensorsmustbestableforatleastfour
consecutivetransmissions.Ifthisisnotthecase,theinformationisnotshownin
theTV80presentation.
Strong
Theinformationprovidedfromthesensorsmustbestableforatleasteight
consecutivetransmissions.Ifthisisnotthecase,theinformationisnotshownin
theTV80presentation.
AGC(AutomaticGainControl)
TheAGC(AutomaticGainControl)functionrunsanautomaticanalysisoftheecho
strength.Duringnormaloperation,Onistherecommended(anddefault)setting.
ManualGain
Thisfunctionallowsyoutoapplyaselectedamountofgaintothereceivercircuitry.If
youdecidetoswitchtheAGCoffyoumustsetthegainmanually.
ThedefaultandrecommendedsettingisMedium.
MultipathFilter
TheMultipathFilterisdesignedtoremedyforreections,spikesandtime-laginthe
sensordata.Theseproblemsmayoccurifneighbouringchannelsareused,orifthe
TV80isdisturbedbyotherhydroacousticsystemsinuseonyourownorothervessels.
Whenyouoperateinareaswithsubstantialreverberationduetothebottomconditions,
orinshallowwaters,youmayexperience“jumps”orspikesinthedatareceivedfrom
thesensors.Sucherrorscanalsobecausedbyothertypesofhydroacousticequipment
SimradTV80ReferenceManual