EasyManua.ls Logo

Smartgen ALC404 - Page 49

Smartgen ALC404
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ALC404 LIGHTING TOWER CONTROLLER USER MANUAL
ALC404 Lighting Tower Controller 2018-11-06 Version 1.1 Page 49 of 83
Category
Parameters
Range
Default
Description
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 3 Set
Function
Config.
(0~119)
22 Common
Shutdown
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 4 Set
Function
Config.
(0~119)
106 1#Light
Output
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 5 Set
Function
Config.
(0~119)
107 2#Light
Output
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 6 Set
Function
Config.
(0~119)
108 3#Light
Output
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 7 Set
Function
Config.
(0~119)
109 4#Light
Output
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Module
Config.
Language Select
(0~1)
0
0 Simplified Chinese
1 English
Power On Mode
(0~4)
0
0 Stop Mode
1 Manual Mode
2 Auto Timer Mode
3 Sunrise/Sunset Mode
4 Remote Start Mode
Password Config
(0~65533)
00318
00318 password is used
to enter into advanced
parameter settings.
Start Interface
Enable
(0~1)
0
0 Disabled 1 Enabled
Start
Interface
Delay
(0~3600)s
3
After enabled, it is the boot
screen duration that user
defined for each start.
Deep Sleep
Enable
(0~1)
0
0 Disabled 1 Enabled
Deep Sleep
(1~100)min
6
After enabled, no keys been

Table of Contents