ALC404 LIGHTING TOWER CONTROLLER USER MANUAL
ALC404 Lighting Tower Controller 2018-11-06 Version 1.1 Page 48 of 83
Category
Parameters
Range
Default
Description
Delay
(0~3600)s
3
Low
Warning
Enable
(0~1)
1
0 Disabled 1 Enabled
Set
Value
(0~1000)kPa
124
Return
Value
(0~1000)kPa
138
Delay
(0~3600)s
5
NOTE: Parameters of ECU_coolant temperature and ECU_oil pressure, only available for EFI genset, are
used for judging alarm situation of coolant temperature and oil pressure that returned from ECU.
Digital
Inputs
Input 1 Set
Function
Config.
(0~59)
04 Remote
Start
Functions please to see 7.9
FUNCTION DEFINITION
OF INPUT PORTS.
Active
(0~1)
0 Close to
activate
0 Close to activate
1 Open to activate
Input 2 Set
Function
Config.
(0~59)
08 1#Light
Feedback
Functions please to see 7.9
FUNCTION DEFINITION
OF INPUT PORTS.
Active
(0~1)
0 Close to
activate
0 Close to activate
1 Open to activate
Input 3 Set
Function
Config.
(0~59)
09 2#Light
Feedback
Functions please to see 7.9
FUNCTION DEFINITION
OF INPUT PORTS.
Active
(0~1)
0 Close to
activate
0 Close to activate
1 Open to activate
Input 4 Set
Function
Config.
(0~59)
10 3#Light
Feedback
Functions please to see 7.9
FUNCTION DEFINITION
OF INPUT PORTS.
Active
(0~1)
0 Close to
activate
0 Close to activate
1 Open to activate
Input 5 Set
Function
Config.
(0~59)
11 4#Light
Feedback
Functions please to see 7.9
FUNCTION DEFINITION
OF INPUT PORTS.
Active
(0~1)
0 Close to
activate
0 Close to activate
1 Open to activate
Relay
Outputs
Output 1 Set
Function
Config.
(0~119)
09 Fuel
Relay Output
Functions please to see
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 2 Set
Function
Config.
(0~119)
035
Energize to
Stop
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.

Table of Contents