Configuring the Switch
3-6
3
Aggregation Port Configures parameters for link aggregation group members 3-84
Port Counters Information Displays statistics for LACP protocol messages 3-86
Port Internal Information Displays settings and operational state for the local side 3-88
Port Neighbors Information Displays settings and operational state for the remote side 3-90
Port Broadcast Control Sets the broadcast storm threshold for each port 3-91
Trunk Broadcast Control Sets the broadcast storm threshold for each trunk 3-91
Mirror Port Configuration Sets the source and target ports for mirroring 3-93
Rate Limit 3-94
Input Port Configuration Sets the input rate limit for each port 3-94
Input Trunk Configuration Sets the input rate limit for each trunk 3-94
Output Port Configuration Sets the output rate limit for ports 3-94
Output Trunk Configuration Sets the output rate limit for trunks 3-94
Port Statistics Lists Ethernet and RMON port statistics 3-95
Address Table 3-99
Static Addresses Displays entries for interface, address or VLAN 3-99
Dynamic Addresses Displays or edits static entries in the Address Table 3-100
Address Aging Sets timeout for dynamically learned entries 3-102
Spanning Tree 3-102
STA 3-102
Information Displays STA values used for the bridge 3-105
Configuration Configures global bridge settings for STA and RSTP 3-107
Port Information Displays individual port settings for STA 3-111
Trunk Information Displays individual trunk settings for STA 3-111
Port Configuration Configures individual port settings for STA 3-114
Trunk Configuration Configures individual trunk settings for STA 3-114
MSTP 3-116
VLAN Configuration Configures priority and VLANs for a spanning tree instance 3-116
Port Information Displays port settings for a specified MST instance 3-118
Trunk Information Displays trunk settings for a specified MST instance 3-118
Port Configuration Configures port settings for a specified MST instance 3-120
Trunk Configuration Configures trunk settings for a specified MST instance 3-120
Table 3-2 Main Menu (Continued)
Menu Description Page

Table of Contents

Other manuals for SMC Networks SMC8126L2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks SMC8126L2 and is the answer not in the manual?

SMC Networks SMC8126L2 Specifications

General IconGeneral
BrandSMC Networks
ModelSMC8126L2
CategorySwitch
LanguageEnglish

Related product manuals