EasyManua.ls Logo

Snom M900 - Emergency Alarm

Snom M900
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
v1.02
Admin and Installation Guide M900 Configuring
Emergency alarm
Seven emergency alarm profiles can be configured on this page. All configured emergency alarm
settings can be selected individually for any handset registered at the base station if that handset has
an emergency alarm function. After an emergency alarm profile has been configured in this menu, it
can be selected for individual handsets on the handset page.
Note: All features of the emergency alarm settings are available on the M70, M80, M85, and M90.
The M65 can be enabled to send an alarm call to the specified alarm number using the factory
settings; the M25 does not have an emergency alarm.
Profile alias. Optional name for alarm profile; will be added to profile number in parentheses.
Alarm type. Select Alarm Button from the drop-down menu to enable the alarm feature. Default
setting: Disabled.
Alarm signal. The Call setting is mandatory. When the alarm button on the handset is pressed,
the handset will call the phone number specified in the handset's Alarm settings (see "Selecting
emergency alarm setting" on page 25).
The following settings apply to the M70, M80, M85, and M90. The M65 uses the default settings
regardless of the setting, except for Howling which is not available on the M65.
Stop Alarm from Handset. This setting establishes whether or not an alarm can be cancelled
from the handset. Default setting: Enabled.
Trigger Delay. Enter the number of seconds from the moment the handset's alarm button is
pressed that the handset will wait before calling the alarm number or, if a pre-alarm delay has
also been configured, before the pre-alarm delay is triggered. Default setting: 0.
Stop Pre-Alarm from Handset. This setting establishes whether or not a pre-alarm can be
cancelled from the handset. Default setting: Enabled.
Pre-Alarm Delay. Enter the number of seconds from the moment the handset's alarm button is
pressed that the handset will wait before calling the alarm number. The display will show the
"Pre-alarm triggered" message, and the emergency ringer, if set, will be played. Default
setting: 0.
Howling (not available on M65). This setting establishes whether or not the handset will emit a
howl while it is dialing the emergency number. Default setting: Disabled.