3. How to Reset Hours Meter
The menus H12, H13 and H14 can be reset by the following procedure.
(1) Set the switch S101-1 on the SV-212 board to ON (upper).
(2) Press the [MENU] key on the control panel. The menu list
appears.
(3) Turn the JOG dial to move the asterisk (*) mark and select
either H12 or H13 or H14. (Display example on right side
shows H12 selected.)
(4) While pressing the [SEARCH] key, turn the JOG dial to
set “0 HOURS”.
(5) Press the [SET] key on the control panel to save the reset
data.
(6) Set the switch S101-1 on the SV-212 board to OFF (lower).