TESTING FAILSAFE
CAUTION: Make sure the aircraft is fully restrained on the ground. If the failsafe is not set
correctly, the aircraft might advance to mid or full throttle. Always remove propellers or
disengage motors from drive systems when testing failsafe on electric power systems.
NOTICE: Failsafe features vary according to receiver. Always consult the receiver instruction
manual for failsafe features. Before ight, ALWAYS conrm failsafe functions as expected.
The aircraft must be congured and binding complete prior to testing the failsafe settings.
To test the function of the failsafe settings:
1. Power on the transmitter and receiver and conrm the controls function properly.
2. Power off the RF signal on the transmitter by double clicking the power button, switching off
RF and touch and hold OK. The throttle and control surfaces should immediately move to the
expected failsafe positions or hold position depending on the failsafe type set during bind.
Throttle should always be set to return to low throttle.
3. Restore the RF signal by double pressing the power button and selecting RF on and
touch and hold OK.