EasyManua.ls Logo

SPX FLOW 030-U3 - Page 46

SPX FLOW 030-U3
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Waukesha Cherry-Burrell
®
Brand Universal 3 Pump
Page 46 95-03103 11/2018
4. Remove the adjusting ring O-ring from the shaft groove on
each shaft.
NOTE: Before installing the new O-rings, inspect the shaft O-
ring groove(s) for damage, and repair or replace the shafts if
required.
NOTE: Inspect the flats on the shaft shoulder and repair or
replace the shafts if required.
5. Remove the 3 stationary seal retaining bolts from each seal
housing (040-U3 pictured).
NOTE: The seal may be removed by loosening 2 screws and
removing the 3rd screw.
6. Remove the flush-side stationary seal (040-U3 pictured).
7. Inspect the seal housing pins for damage, and repair or
replace them as necessary. If the pins are loose, replace
them with new ones.
8. Remove the wave spring (040-U3 pictured).
Figure 72 - Adjusting ring O-ring
Figure 73 - Remove seal retaining
bolts
Figure 74 - Remove stationary seal
Figure 75 - Remove wave spring

Table of Contents