Waukesha Cherry-Burrell
®
Brand Universal 3 Pump Maintenance
11/2018 95-03103 Page 47
9. Remove the stationary seal O-ring (040-U3 pictured).
10. Remove the 4 seal housing bolts (040-U3 pictured).
11. Remove the seal housing (040-U3 pictured). The arrow in
Figure 78 shows the seal housing O-ring location on pump
sizes 130-U3 and smaller.
12. (130-U3 and smaller) Remove the seal housing O-ring from
around the shaft ring. See Figure 78 for the seal housing O-
ring location.
Figure 76 - Seal O-ring location
Figure 77 - Seal housing bolts
Figure 78 - Remove seal housing
Figure 79 - Remove seal housing O-
ring