143
Parameters SH5.0RT SH6.0RT
Max. AC output current 7.6 A
9.1 A
Rated AC voltage 3 / N / PE, 220 / 380 V; 230 / 400 V; 240 / 415 V
AC voltage range 270 - 480 Vac
Rated grid frequency/Grid
frequency range
50Hz / 45 - 55Hz, 60Hz / 55 - 65Hz
THD
< 3 % (of rated power)
DC current injection < 0.5 % In
Power factor
> 0.99 / 0.8 leading to 0.8 lagging
Protection&Function
LVRT Yes
Anti-islanding protection Yes
AC short circuit protection Yes
Leakage current protection Yes
DC switch (solar) Yes
DC Overcurrent Protection
(battery)
Yes
Over-voltage category III [Mains], II [PV] [Battery]
SPD DC Type II / AC Type II
Battery input reverse polarity
protection
Yes
Parallel operation on grid port
/ Max. No. of inverters
Master-slave mode / 5 ** (need same inverters type)
System Data
Max. efficiency
98.0 % 98.2 %
European efficiency
97.2 % 97.5 %
Isolation method (solar /
battery)
Transformerless / Transformerless
Degree of protection IP65
Operating ambient tempera-
ture range
-25 ℃ - 60 ℃
Allowable relative humidity
range (Non-condensing)
0 - 100 %
Cooling method Natural convection
Max. operating altitude 4000 m (> 3000 m derating)
Noise (Typical) 30 dB(A)
Display LED
Communication
RS485, WLAN, Ethernet, CAN, 4 × DI, 1 × DO
User Manual 11 Appendix