150
Parameters SH5.0RT-20 SH6.0RT-20
Peak output power on single
phase ****
2000 VA (≥9.6kWh) 2200 VA (≥12.8kWh)
Rated output current for
backup load during on grid
mode
3 x 18.5 A
* Depending on the connected battery.
** Germany is available for 2 inverters parallel in maximum if no ripple control is used in
system.
*** Can be reached only if PV and battery power is sufficient.Detail compatibility for backup
under off-grid scenario can be referred to the user manual.
**** Peak power only for Resistive loads. Detail refer to SHRT backup output power
document.
Parameters SH8.0RT-20 SH10RT-20
PV Input
Recommended max. PV in-
put power
12000 W 15000 W
Max. PV input voltage
1000 V 1000 V
Min. PV input voltage / Start-
up voltage
200 V / 250 V 200 V / 250 V
Rated input voltage
600 V 600 V
MPP voltage range
200 V - 950 V 200 V - 950 V
MPP voltage range for rated
power
330 V - 850 V 280 V - 850 V
No. of MPPTs 2
Max. number of PV strings
per MPPT
1 / 1
Max. PV input current 27 A (13.5 A / 13.5 A)
Max. current for input
connector
30 A
Short-circuit current of PV
input
36 A (18 A / 18 A)
54 A (18 A / 36 A)
Battery Data
Battery type Lithium battery
Battery voltage 150 V - 600 V
Max. charge / discharge
current
30 A */ 30 A *
Max. charge / discharge
power
10600 W / 10600 W 10600 W / 10600 W
11 Appendix User Manual