151
Parameters SH8.0RT-20 SH10RT-20
AC Input and Output Data
Max. AC input power to
battery
18600 W
20600 W
Max. AC input power from
grid
18600 W 20600 W
Rated AC output power
8000 W 10000 W
9999W for Australia
Rated AC output apparent
power
8000 VA
10000 VA
9999W for Australia
Rated AC output current 12.1 A
15.2 A
Rated AC voltage 3 / N / PE, 220 / 380 V; 230 / 400 V; 240 / 415 V
AC voltage range 270 - 480 Vac
Rated grid frequency 50Hz
Grid frequency range 45 – 55Hz
Harmonic THD
< 3 % (of rated power)
DC current injection < 0.5 % In
Power factor at Rated power
/ Adjustable power factor
> 0.99 / 0.8 leading to 0.8 lagging
Feed-in phases/connection
phases
3 / 3
Protection&Function
Grid monitoring Yes
Anti-islanding protection Yes
DC reverse polarity
protection
Yes
DC switch (solar) Yes
DC Overcurrent Protection
(battery)
Yes
Surge Protection DC Type II / AC Type II
Parallel operation on grid port
/ Max. No. of inverters
Master-slave mode / 5 **
Battery input reverse polarity
protection
Yes
System Data
Max. efficiency
98.4 % 98.4 %
European efficiency
97.9 % 97.9 %
Topology (solar / battery)
Transformerless / Transformerless
Degree of protection IP65
User Manual 11 Appendix