1 Safety User Manual
4
Provide sufficient ventilation for lead-acid battery systems to prevent
flames and sparks from the explosive hydrogen gas that the batteries
release.
Due to the dangers of hydrogen gas and battery electrolyte:
locate batteries in a designated area, complying with the local
regulations;
protect the enclosure against destruction;
do not open or deform the battery module;
whenever working on the battery, wear suitable personal protective
equipment (PPE) such as rubber gloves, rubber boots and goggles;
rinse acid splashes thoroughly with clear water for a long time and
consider consulting a doctor.
Improper settings or maintenance can permanently damage the
battery.
Incorrect inverter parameters will lead to the premature aging of
battery.
Energy Meter
Lethal voltages and danger to life due to electric shock!
Only use the Energy Meter in a dry environment and keep it away
from liquids.
Install the Energy Meter in the switch cabinet only and ensure that the
connection areas for the line and the neutral conductors are behind
an insulting cover or have contact protection.
Install an external disconnect switch between the Energy Meter and
the grid-connected point. The external disconnector must be close to
the Energy Meter and easily accessible.
Disconnect the Energy Meter from voltage sources before cleaning.
The Energy Meter must be cleaned with a dry cloth only.