5 Mechanical Mounting
5.1 Safety during Mounting
In order to avoid electric shock or other injury, be sure there is no
electricity or plumbing installations before drilling holes.
Risk of injury due to improper handling
The weight can cause injuries, serious wounds, or bruise.
Always follow the instructions when moving and positioning the
inverter.
System performance loss due to bad ventilation
The inverter requires good ventilation during operation. Keep it
upright and nothing covering the heat sink.
Wear gloves to avoid scratches when mounting the inverter.
5.2 Location Requirements
The inverter with IP65 can be installed indoors or outdoors.
Selecting an optimal location for the inverter is critical for its operating safety as
well as the expected efficiency and service life. Considerations for the location
include:
1. The structure should be capable of withstanding a force of four times the
weight of the inverter.
2. Install the inverter where it is convenient for installation, cable connection
and service.
3. The location should be not accessible to children.