User Manual 8 Troubleshooting and Maintenance
73
Slave DSP communication
fault.
recovery or restart the system.
BDC internal permanent faults.
BDC temperature sensor
warnings
1. Check and clean the heat sink.
2. Check whether the inverter is
installed in sunlight or the ambient
temperature of the enclosure
exceeds 45℃.
3. Restart the system.
Transformer direction
recognition error.
1. The inverter can normally be
connected to the grid but
charge/discharge has stopped.
2. Wait a moment for system
recovery or restart the system.
For Battery Side
For the battery faults, please consult the battery manufacturer for a solution.
Battery average
under-voltage fault.
1. The inverter can normally be
connected to the grid but
charge/discharge has stopped.
2. Wait a moment for system recovery
or restart the system.
Battery over-temperature
fault.
1. The inverter can normally be
connected to the grid but
charge/discharge has stopped.
2. Check the ambient temperature of
the battery location.
3. Wait a moment for system recovery
or restart the system.
Battery
under-temperature fault.
Instantaneous battery
over-voltage.
1. The inverter can normally be
connected to the grid but
charge/discharge has stopped.
2. Wait a moment for system recovery
or restart the system.
Battery average
over-voltage fault.
Abnormal communication
between battery and the
hybrid inverter.
1. The inverter can normally be
connected to the grid but
charge/discharge has stopped.
2. Check the battery type and
communication connection. For
lead-acid batteries, you should
manually set the battery type.
3. Wait a moment for system recovery