    Cindy WilliamsSep 7, 2025
    Why SUNWARD Excavators turbocharger noise or excessive vibration?
    • J
      Jesus PorterSep 7, 2025
      If you notice excessive noise or vibration from the turbocharger in your SUNWARD Excavators, check the turbocharger lubrication piping to ensure sufficient lubrication of the bearings. Also, inspect the turbine blades for breakage by removing the exhaust pipe and air intake hose. For bearing wear, piping leakage, or improper clearance between the turbine and its case, contact your designated distributor.
  • V
    Valerie KimAug 22, 2025
    How to troubleshoot starting problems with SUNWARD Excavators engine?
    • H
      hickslaurenAug 22, 2025
      If your SUNWARD Excavators engine runs but struggles or fails to start, possible causes include: being out of fuel (add fuel), using the wrong or polluted fuel (drain and replace with proper fuel), defective wiring (check and repair the starting circuit), insufficient battery power (charge or replace the battery), a clogged air filter (clean or replace the filter), a clogged fuel filter (clean or replace the filter), internal fuel system leaks (check and repair leaks), a fuel manual pump spring up (push down and secure the hand wheel), air in the fuel system (bleed the air), or start engine malfunction (use manual pump to bleed air). If all else fails, the start motor may need replacement.
  • R
    Richard BergerSep 5, 2025
    How to fix SUNWARD SWE155F Excavators display screen that does not work?
    • J
      Jon BurtonSep 5, 2025
      If your SUNWARD Excavators display screen isn't working, start by checking the fuse and replace it if it's blown. If the fuse is fine, inspect the wire circuit for any defects and repair as needed. If the display screen is damaged, contact your designated distributor.
  • M
    Matthew JamesSep 3, 2025
    Why displayed temperature of coolant do not reflect real temperature in SUNWARD Excavators?
    • J
      Jacqueline SmithSep 3, 2025
      If the displayed coolant temperature on your SUNWARD Excavators does not match the actual temperature, it may be due to a defective temperature sensor. For a defective temperature sensor, defective wiring circuit or defective indicator, contacting your designated distributor for assistance is recommended.
  • Y
    ymaloneSep 2, 2025
    What causes hydraulic cylinder unable to lift loads in SUNWARD SWE155F?
    • M
      Mitchell Jennings MDSep 2, 2025
      If the hydraulic cylinder of your SUNWARD Excavators is acting but can't lift loads, it could be due to main pump wear, low pressure in the main safety valve, a clogged suction filter (clean or replace it), or a leak in the pump suction pipe (check the piping). If the hydraulic cylinder is worn out and causing internal leaks, consider replacing the piston ring or contacting distributor.
  • C
    Crystal RobinsonAug 31, 2025
    Why SUNWARD SWE155F Excavators exhaust gas is white?
    • S
      Sean TurnerAug 31, 2025
      If your SUNWARD Excavators is producing white exhaust gas, it could be due to improper fuel (drain and replace with proper fuel) or the engine temperature being too low (run the engine to warm up). For a defective thermostat or coolant leaks into the engine cylinder, contact your designated distributor.
  • C
    Colton LewisAug 30, 2025
    Why SUNWARD Excavators shows abnormal fuel indication?
    • A
      Amanda RobertsAug 30, 2025
      If your SUNWARD Excavators shows an abnormal fuel indication, the oil level sensor might be defective (check, repair, or replace it) or there could be a defective wiring circuit (check and repair it). For a defective indicator or wiring circuit issues, contacting your designated distributor for assistance is recommended.
  • M
    Margaret WiseAug 29, 2025
    Why is the hydraulic oil overheating in my SUNWARD SWE155F Excavators?
    • W
      William MejiaAug 29, 2025
      If your SUNWARD Excavators hydraulic oil is overheating, ensure you are using the correct hydraulic oil and that the oil level is at the specified level. If the oil is polluted, filter it or drain and refill with proper oil. Also, check for radiator clogging (clean the radiator and front drainer) and filter clogging (clean or replace the filter). For pump suction pipe leakage, main pump wear, or safety valve improper adjustment, contact distributor.
  • C
    Christopher BriggsAug 27, 2025
    What to do if SUNWARD SWE155F exhaust gas is black?
    • R
      Robin JohnsonAug 28, 2025
      If your SUNWARD Excavators is producing black exhaust gas, it could be due to improper fuel (drain and replace with proper fuel) or a clogged intake system (check, clean, and replace the intercooler if necessary). For intake piping damage, intercooler clogging, unpunctual ejection oil pump, polluted ejection nozzle, or a defective engine main block/body, contact your designated distributor.
  • N
    Nancy ParrishAug 27, 2025
    How to improve slow hydraulic function in SUNWARD SWE155F Excavators?
    • K
      Kelly CampbellAug 27, 2025
      If the hydraulic function of your SUNWARD Excavators is slow, consider the following: Check and replenish the hydraulic oil level to the specified mark. Allow the machine to warm up until the hydraulic oil reaches around 50°. Ensure you are using the correct type of oil for the ambient temperature. Adjust the engine revs. For issues related to main pump wear, pilot oil circuit malfunction, or a blocked main suction oil pump, contact distributor.

Summary

1 SAFETY RULES

1.1 SAFETY LABELS

Understand and maintain safety labels for proper machine operation and warning.

1.2 GENERAL SAFETY RULES

General safety rules and precautions for operating and maintaining the machine.

1.3 SAFE OPERATION INSTRUCTIONS

Step-by-step instructions and guidelines for safe machine operation.

1.4 SAFETY MAINTENANCE INFORMATION

Safety guidelines to follow during machine maintenance and servicing.

2 TRANSPORTATION AND STORAGE

2.1 TRANSPORT

Procedures and regulations for transporting the excavator safely and legally.

2.2 STORAGE

Guidelines for proper storage of the excavator to prevent damage and degradation.

3 OPERATION

3.1 MACHINE ASSEMBLY DRAWING

Visual representation of the excavator's main components and their identification.

3.2 CONTROL DEVICE INSTRUCTIONS

Detailed explanation of the function and operation of all control devices.

3.3 OTHER OPERATION INSTRUCTIONS

Additional operational procedures and tips not covered elsewhere.

3.4 MACHINE OPERATION AND CONTROL

Comprehensive guide to operating and controlling the excavator's functions.

4 MAINTENANCE

4.1 MAINTENANCE INFORMATION

Essential information and procedures for effective machine maintenance.

4.2 OIL, COOLANT AND FILTER

Specifications, types, and replacement procedures for oils, coolant, and filters.

4.3 TIGHTENING TORQUE SPECIFICATION

Correct torque values for tightening bolts, nuts, and hoses.

4.4 MAINTENANCE SCHEDULE

Regular maintenance tasks and intervals based on operating hours.

4.5 MACHINE MAINTENANCE INTERVAL

Maintenance procedures organized by operating hours and specific tasks.

4.6 GENERAL TROUBLE SHOOTING

Guidance on identifying and resolving common engine, electrical, and hydraulic issues.

5 TECHNICAL SPECIFICATION

5.1 SW155 F TECHNICAL SPECIFICATION

Detailed technical data, dimensions, and performance parameters for the SW155F.

6 NOTE FOR SAFETY

Attachment and Operation Safety Notes

Safety precautions for using attachments and general operational safety.

7 MANUFACTURER INFORMATION

Distributor Information

Contact details and addresses for overseas distributors and subsidiaries.

SUNWARD SWE155F Specifications

General IconGeneral
BrandSUNWARD
ModelSWE155F
CategoryExcavators
LanguageEnglish

Related product manuals