8-20 ELECTRICAL SYSTEM
IGNITION COIL RESISTANCE
Disconnect the ignition coil lead wires and spark plug cap.
Measure the ignition coil resistance in both the primary and sec-
ondary windings using the multi circuit tester. If the resistance in
both the primary and secondary windings is close to the speci-
fied values, the windings are in sound condition.
# Ignition coil resistance
Primary : 0.05 1.0 Ω
ΩΩ
Ω (
+ Terminal
- Terminal)
Secondary : 10.5 19.0 kΩ
ΩΩ
Ω
(Spark plug cap
+ Terminal)
$ 09900-25008: Multi circuit tester set
) Tester knob indication: Resistance (Ω
ΩΩ
Ω)
PICKUP COIL PEAK VOLTAGE
NOTE:
Make sure all of the couplers are connected properly.
Remove the seat. (!7-5)
Disconnect the CDI unit coupler
1.
Measure the pickup coil peak voltage in the following procedure:
Connect the multi circuit tester with the peak volt adaptor as
follows.
Pickup coil:
+ Probe...Green/White lead wire
- Probe...Black/Yellow lead wire
$ 09900-25008: Multi circuit tester set
"
When using the multi circuit tester and peak volt adap-
tor, refer to the appropriate instruction manual.
Generator
Pickup coil
B/Y
G/W
G/W
B/Y
Generator
coupler
Wiring
harness
coupler
Peak volt adaptor