ELECTRICAL SYSTEM 6-7
CHARGING SYSTEM
TROUBLESHOOTING
Battery runs down quickly
Step 1
1) Check accessories which use excessive amounts of electricity.
Are accessories being installed?
Step 2
1) Check the battery for current leaks. (6-8)
Is the battery current leaks OK?
Step 3
1) Measure the regulated voltage between the battery terminals. (6-9)
Is the regulated voltage OK?
Step 4
1) Measure the resistance of the generator coil. (6-9)
Is the resistance of generator coil OK?
YES Remove accessories.
NO Go to Step 2.
YES Go to Step 3.
NO
Short circuit of wiring harness.
Faulty electrical equipment.
YES
Faulty battery.
Abnormal driving condition.
NO Go to Step 4.
YES Go to Step 5.
NO
Faulty generator coil.
Disconnected lead wires.
Generator
Regulator/rectifier
Ignition
switch
Load
Fuse
10A
Battery
B/W
RW/R
W/R R/W
B/W