6-16 ELECTRICAL SYSTEM
STARTER MOTOR INSTALLATION
• Tighten the starter motor lead wire screw 1 and starter motor
mounting bolts 2.
STARTER RELAY INSPECTION
• Remove the seat. (5-4)
• Remove the starter relay 1 from the frame center cover.
• Disconnect the starter relay coupler 2.
First check the insulation between A and B terminals with the
multi-circuit tester. Then apply 12 V to terminals as shown and
check the continuity between A and B. If there is no continuity,
replace the starter relay with a new one.
09900-25008: Multi-circuit tester set
Tester knob indication: Continuity test ()
Do not apply battery voltage to the starter relay for
more than five seconds, since the relay coil may over-
heat and get damaged.