6-22 ELECTRICAL SYSTEM
Repeat the above procedure a few times and measure the
highest pick-up coil peak voltage.
Tester knob indication: Voltage ()
Pick-up coil peak voltage: 1.5 V and more
If the peak voltage measured on the CDI unit coupler is lower
than the standard value, measure the peak voltage on the gen-
erator coupler as follows.
Remove the left frame cover. (5-4)
Disconnect the generator coupler 2 and connect the
multi-circuit tester with the peak volt adaptor as follows.
Pick-up coil: + Probe...Brown lead wire
- Probe...Ground
Measure the pick-up coil peak voltage in the same manner as on
the CDI unit coupler.
Tester knob indication: Voltage ()
Pick-up coil peak voltage: 1.5 V and more
If the peak voltage on the generator coupler is within the specifi-
cation, but on the CDI unit coupler is not within specification,
replace the wiring harness with a new one. If both peak voltages
are not within specification, replace the generator coil with a new
one.
PICK-UP COIL RESISTANCE
Remove the left frame cover. (5-4)
Disconnect the generator coupler 1.
Measure the resistance with the multi-circuit tester. If the resis-
tance is not within the standard range, replace the generator
coil.
09900-25008: Multi-circuit tester set
Tester knob indication: Resistance ()
Pick-up coil resistance: 150 – 230
(Brown – Ground)
Peak volt adaptor
Pick-up
coil
W/R Br
Generator
PartShark.com