Creating and Loading Hex Images 6-17
Insufficient data available to
complete record
-21 A Symbol HEX file download was attempted but the HEX file is invalid. Ensure the file is in Symbol HEX
file format.
Invalid Symbol HEX file -23 A Symbol HEX file download was attempted but the HEX file is invalid. Ensure the file is in Symbol HEX
file format.
Unrecognized or unsupported HEX
record
-24 The Symbol HEX file being downloaded contains an invalid or unrecognized HEX record. Ensure the file
is in proper Symbol HEX file format.
Invalid data in HEX file -25 The Symbol HEX file being downloaded contains invalid data. Ensure the file is in proper Symbol HEX
file format with valid HEX data.
Exceeded max size -26 The download file is too large to fit into the space allocated for it. Either make the file smaller or
increase the space allocated for it by altering the partition table.
Partition is not valid on this device -27 The downloaded file specifies a partition entry that does not exist on the device. Only download files
that are valid for this device, or change the partition table so that the new file is valid on the device.
Wrong destination code -28 A specific partition was chosen from the Main Menu (not Auto Select) but the file selected for
download was for another partition. Ensure that the partition selected from the Main Menu matches
the file selected for download.
File type does not support IPL Auto
Select
-29 Auto Select cannot load Monitor, Power Micro, and Partition Table. Select the appropriate area, and try
again.
Non-contiguous record found -30 A Symbol HEX file download was attempted but the HEX file is invalid. Ensure the file is in Symbol HEX
file format.
Timed Out - No data -31 IPL was waiting for data from the source device but timed out before receiving any. Check the source
device connectivity and retry.
Fail: Buffer Overrun -32 The serial port device could not keep up with incoming data. Retry the serial download with a lower
baud rate.
Partition Table not Valid -33 The size of flash memory is different than that described in the partition table. Retry the download with
the correct partition table file.
Invalid file format -34 The file format is invalid. IPL only supports Symbol HEX files.
Table 6-5. IPL Errors (Continued)
Error Text Error Number Probable Cause