COMMAND CODE: SET-TH-MSG (Contd)
EXAMPLE
Input:
SET-TH-MSG::SHELF:135::,100,100,80;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 135 COMPLD
;
This example, tagged as command 135, sets the nonswitching message delay to 100 ms, the switching
message delay to 100 ms, and the holdover message delay to 80 s.