Issue 2: Sep 99 TMSL 097-44018-26
Page 35
COMMAND CODE: ED-EQPT (Contd)
INPUT FORMAT (Contd)
aid parameter value meaning
MRC-a framing (null) (not applicable)
troublecode
portseverity
osc1 NONE oscillator 1 (OSCA) is not equipped
QTZ oscillator 1 (OSCA) is quartz clock
RB oscillator 1 (OSCA) is rubidium clock
osc2 NONE oscillator 1 (OSCA) is not equipped
QTZ oscillator 1 (OSCA) is quartz clock
RB oscillator 1 (OSCA) is rubidium clock
integration (null) (not applicable)
clklevel
alarmlead
signaltype
TO-c framing CAS channel associated signaling
CAS4 channel associated signaling with cyclic redundancy check 4
CRC4 common channel signaling with cyclic redundancy check 4
D4 D4 framing
ESF ESF framing
FAS common channel signaling
troublecode INH all outputs are squelched upon card failure
ALW AIS is sent on all outputs upon card failure
Note: If any port on the TO card is set for ANALOG, the troublecode must be set
to INH.
portseverity MJ port failure causes major alarm
MN port failure causes minor alarm
osc1 (null) (not applicable)
osc2
integration
clklevel
alarmlead
signaltype