AC Power Supply
Operating Temperature: 0 °C to +50 °C (+32 °F to +122 °F)
Maximum Rate of Change: 8 °C per hour
Storage Temperature: -55 °C to +85 °C (-67 °F to +185 °F)
Humidity: To 95% non-condensing
Operating Altitude: Maximum 4 km (2.49 mi. or 13147 ft.)
Front Panel Display: Vacuum Fluorescent Display (VFD) 4.38” x 0.88" (11.13cm x 2.24 cm). 160X16
pixels. Displays startup messages, clock status, time and day of year, and
interactive clock functions. The TIME button displays Time and Day of Year
(TOD) on one full-height line.
Keypad: 0–9, UP, DOWN, LEFT, RIGHT, ENTER, CLR, TIME, STATUS, MENU
Serial I/O: Full user-selectable RS-232/422 communication protocol up to 19200 baud
Input:
Input connector: IEC 320 connector
Input voltage range: UL: 100 – 240 VAC
Universal, 90 – 264 VAC and 110 – 370 VDC
Input freq. range: 47 Hz – 440 Hz
Output: +5.2 V (5.0 to 5.4 V), 25 watts, 0 to 5 amps
+12 V (11.4 to 12.6 V), 45 watts, 0 to 3.8 amps
-12 V (-11.4 to -12.6 V) 32 watts, 0 to 2.7 amps
Wattage: 104 watts
Power Supply Status: The Fault Detector monitors all three output voltages and provides a visual
(panel LED) and fault status if any output voltage decreases by 10%.
Alarm Status LED: Green LED on with no fault and AC power applied. Green LED off with fault or no
AC power applied.
Fan: Exhaust 3-6 CFM